Publication date: Available online 7 June 2018
Source:The Journal of Emergency Medicine
Author(s): Dong Keon Lee, Yong Sung Cha, Oh Hyun Kim, Kyoung Chul Cha, Kang Hyun Lee, Sung Oh Hwang, Hyun Kim, Young Hwan Lee, Minjung Kathy Chae
BackgroundAn automatic simultaneous sternothoracic cardiopulmonary resuscitation (SST-CPR) device is an apparatus that performs CPR by providing simultaneous cyclic compressions of the thorax with a thoracic strap and compression of the sternum with a piston.ObjectiveThis study was conducted to compare the hemodynamic effects of CPR with an automatic SST-CPR device to those with standard CPR (STD-CPR) in cardiac arrest patients.MethodsA randomized trial was performed on victims of out-of-hospital cardiac arrest resistant to initial 20 min of CPR after emergency department (ED) arrival. Patients were instrumented with femoral arterial and internal jugular venous lines before enrollment. Informed consent was waived per protocol. Patients were randomized to SST-CPR or STD-CPR based on the day of the month. The primary outcome was a comparison of the mean estimated coronary perfusion pressure (CPP) between SST-CPR and STD-CPR. The secondary outcome was a comparison of compression arterial systolic pressure, compression arterial diastolic pressure, right atrial systolic pressure, right atrial diastolic pressure, return of spontaneous circulation rate, survival to hospital admission, survival at 30 days, favorable neurologic outcomes at 30 days, and adverse events between two groups.ResultsOf 62 patients with non-traumatic, adult, out-of-hospital cardiac arrest who presented to the ED, 24 received CPR with an automatic SST-CPR device (SST-CPR group), and 38 received standard CPR (STD-CPR group). Acquisition and analysis of hemodynamic data were completed in 11 (46%) patients in the SST-CPR group and 14 (37%) patients in the STD-CPR group. Compression arterial systolic pressure, right atrial systolic/diastolic pressures, and end-tidal carbon dioxide tension were not different between the two groups. Median compression arterial diastolic pressure (femoral arterial pressure during relaxation) was 20 mm Hg (mean 22 mm Hg; 95% confidence interval [CI] 5 to 38 mm Hg) and 0 mm Hg (mean −2 mm Hg; 95% CI −21 to 18 mm Hg) in the SST-CPR group and the STD-CPR group (p = 0.002), respectively. Median estimated CPP was 10 mm Hg (mean 16 mmHg; 95% CI 1 to 31 mm Hg) and 2 mm Hg (mean 4 mm Hg; 95% CI −4 to 12 mm Hg) in the SST-CPR group and the STD-CPR group (p = 0.017), respectively.ConclusionsCPR with an automatic SST-CPR device results in higher estimated CPP compared to standard CPR in patients with non-traumatic, out-of-hospital cardiac arrest.
from Emergency Medicine via xlomafota13 on Inoreader https://ift.tt/2LZDqVz
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
This feed no longer exists. Cambridge Journals Online and Cambridge Books Online have been replaced by Cambridge University Press’s new acad...
-
Abstract In this work, novel thin-film composite forward osmosis (TFC-FO) hollow fiber membranes were fabricated by modifying polyamide ac...
-
Objectives: Opioids and benzodiazepines are commonly used to provide analgesia and sedation for critically ill children with cardiac disease...
-
Objective: Inotropic and vasopressor drugs are routinely used in critically ill patients to maintain adequate blood pressure and cardiac ou...
-
Academic Emergency Medicine, EarlyView. from Emergency Medicine via xlomafota13 on Inoreader https://ift.tt/2Lq7OXW
-
Abstract The dispersion properties of Love waves are utilized for the fabrication of sensor devices in the different material environments...
-
Plasminogen activator inhibitor-1 gene polymorphisms in systemic lupus erythematosus: is there a risk for lupus nephritis among Egyptians? A...
-
EMS providers should be on high alert for fraud and forgery in the patient care report from EMS via xlomafota13 on Inoreader https://ift.t...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου