Objectives: To investigate how compensating for endotracheal tube leaks by targeting the leak-compensated tidal volume affects measured physiologic and ventilator variables during neonatal mechanical ventilation. Design: Retrospective observational study. Setting: A level III Neonatal ICU. Patients: We enrolled 30 neonates who were ventilated using synchronized intermittent positive pressure mode with volume guarantee and had at least 12 hours of continuous detailed recording of ventilation variables. Interventions: Infants were treated using the Dräger VN500 ventilator (Dräger, Lübeck, Germany), which uses a proprietary algorithm to measure and compensate for endotracheal tube leaks. Eleven were ventilated without leak compensation and 19 with leak compensation. Measurements and Main Results: Detailed ventilation data were collected and analyzed at 1 Hz, with intermittent blood gas values. The percentage of leak was less than 20% in 73% of leak-compensated inflations, and the volume of the leak compensation was less than 1 mL/kg in 97.3% of inflations. Between the two groups, ventilation variables were comparable, except the percentage of leak that was significantly (p = 0.005) higher in the recordings with leak compensation. Without leak compensation, the mean expired tidal volume was maintained very close to the set level up to 50% leak, but with leaks greater than 50%, it declined progressively. With leak compensation, the mean leak-compensated expired tidal volume was well maintained even with leak greater than 90% although with large variability. Without leak compensation, the difference between the maximum allowed inflating pressure and the peak inflating pressure decreased progressively as the leak increased. This did not occur with leak compensation. The median PCO2 was slightly higher with leak compensation. Conclusions: During volume guarantee ventilation with a Dräger VN500 ventilator, without leak compensation the expired tidal volume declined after 50% leak. With leak compensation, the tidal volume was maintained even with a large leak. With leak compensation, there was a more stable peak inflating pressure, although the PCO2 was slightly higher. This work was performed at the Neonatal ICU, The Rosie Hospital, Cambridge, United Kingdom. Supplemental digital content is available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal’s website (https://ift.tt/2gIrZ5Y). Dr. Morley received funding from Fisher and Paykel Healthcare, Acutronic Medical Instruments, and Chiesi Pharmaceuticals (honorarium for lectures), and he disclosed off-label product use of Drager Medical Neonatal Ventilator VN500. The remaining authors have disclosed that they do not have any potential conflicts of interest. For information regarding this article, E-mail: gusztav.belteki@addenbrookes.nhs.uk ©2018The Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies
from Emergency Medicine via xlomafota13 on Inoreader https://ift.tt/2K4lDiD
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Champion EMS is currently seeking a Communications Center Manager. Champion EMS is based out of Longview, Texas, serving the East Texas area...
-
from EMS via xlomafota13 on Inoreader http://ift.tt/2sbML2K
-
Remove ads BioMed Research International Validity and Reliability of the Polish Adaptation of the CHAMPS Physical Activity Questionnaire Th...
-
Abstract Objectives Emergency departments (EDs) commonly analyze cases of patients returning within 72 hours of initial ED discharge as...
-
Abstract Introduction In recent years, platelet-rich plasma (PRP) has emerged as a promising autologous biological treatment modality fo...
-
from EMS via xlomafota13 on Inoreader http://ift.tt/2sbML2K
-
from EMS via xlomafota13 on Inoreader http://ift.tt/2sbML2K
-
ORIGINAL ARTICLES Cone-beam computed tomography versus orthopantomography in sinus lift procedures: Two-dimensional versus three-dimension...
-
Haemovigilance programme of India: Comparative analysis of transfusion reactions reported over a 5-year period through two reporting formats...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου