Objective: Plasma interleukin-1 beta may influence sepsis mortality, yet recombinant human interleukin-1 receptor antagonist did not reduce mortality in randomized trials. We tested for heterogeneity in the treatment effect of recombinant human interleukin-1 receptor antagonist by baseline plasma interleukin-1 beta or interleukin-1 receptor antagonist concentration. Design: Retrospective subgroup analysis of randomized controlled trial. Setting: Multicenter North American and European clinical trial. Patients: Five hundred twenty-nine subjects with sepsis and hypotension or hypoperfusion, representing 59% of the original trial population. Interventions: Random assignment of placebo or recombinant human interleukin-1 receptor antagonist x 72 hours. Measurements and Main Results: We measured prerandomization plasma interleukin-1 beta and interleukin-1 receptor antagonist and tested for statistical interaction between recombinant human interleukin-1 receptor antagonist treatment and baseline plasma interleukin-1 receptor antagonist or interleukin-1 beta concentration on 28-day mortality. There was significant heterogeneity in the effect of recombinant human interleukin-1 receptor antagonist treatment by plasma interleukin-1 receptor antagonist concentration whether plasma interleukin-1 receptor antagonist was divided into deciles (interaction p = 0.046) or dichotomized (interaction p = 0.028). Interaction remained present across different predicted mortality levels. Among subjects with baseline plasma interleukin-1 receptor antagonist above 2,071 pg/mL (n = 283), recombinant human interleukin-1 receptor antagonist therapy reduced adjusted mortality from 45.4% to 34.3% (adjusted risk difference, -0.12; 95% CI, -0.23 to -0.01), p = 0.044. Mortality in subjects with plasma interleukin-1 receptor antagonist below 2,071 pg/mL was not reduced by recombinant human interleukin-1 receptor antagonist (adjusted risk difference, +0.07; 95% CI, -0.04 to +0.17), p = 0.230. Interaction between plasma interleukin-1 beta concentration and recombinant human interleukin-1 receptor antagonist treatment was not statistically significant. Conclusions: We report a heterogeneous effect of recombinant human interleukin-1 receptor antagonist on 28-day sepsis mortality that is potentially predictable by plasma interleukin-1 receptor antagonist in one trial. A precision clinical trial of recombinant human interleukin-1 receptor antagonist targeted to septic patients with high plasma interleukin-1 receptor antagonist may be worthy of consideration. Copyright (C) by 2017 by the Society of Critical Care Medicine and Wolters Kluwer Health, Inc. All Rights Reserved.
from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2goPLYj
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Purpose Children with sagittal craniosynostosis (SC) are at risk of developing raised intracranial pressure (ICP). This is thou...
-
Abstract Objective Among different PET tracers, 18 F-fludeoxyglucose (FDG) and 11 C-choline are known to have a high tumor uptake correl...
-
Urology from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/1WbRhbQ
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2aggaBB
-
Resuscitation from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/1N8kkFH
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2gDH2gG
-
Abstract Background Poor indoor air quality is a great problem in schools due to a high number of students per classroom, insufficient o...
-
Alternative treatments for opioid use disorder and music with Dr. Ed Boyer Join Dan (@drusyniak) &Howard (@heshiegreshie) as they speak...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου