Objectives: To determine the feasibility of delivering inhaled treprostinil during mechanical ventilation and spontaneous unassisted ventilation using the Tyvaso Inhalation System and the vibrating mesh nebulizer. We sought to compare differences in fine particle fraction, and absolute inhaled treprostinil mass delivered to neonatal, pediatric, and adult models affixed with a face mask, conventional, and high-frequency ventilation between Tyvaso Inhalation System and with different nebulizer locations between Tyvaso Inhalation System and vibrating mesh nebulizer. Design: Fine particle fraction was first determined via impaction with both the Tyvaso Inhalation System and vibrating mesh nebulizer. Next, a test lung configured with neonatal, pediatric, and adult mechanics and a filter to capture medication was attached to a realistic face model during spontaneous breathing or an endotracheal tube during conventional ventilation and high-frequency oscillator ventilator. Inhaled treprostinil was then nebulized with both the Tyvaso Inhalation System and vibrating mesh nebulizer, and the filter was analyzed via high-performance liquid chromatography. Testing was done in triplicate. Independent two-sample t tests were used to compare mean fine particle fraction and inhaled mass between devices. Analysis of variance with Tukey post hoc tests were used to compare within device differences. Setting: Academic children's hospital aerosol research laboratory. Measurements and Main Results: Fine particle fraction was not different between the Tyvaso Inhalation System and vibrating mesh nebulizer (0.78 +/- 0.04 vs 0.77 +/- 0.08, respectively; p = 0.79). The vibrating mesh nebulizer delivered the same or greater inhaled treprostinil than the Tyvaso Inhalation System in every simulated model and condition. When using the vibrating mesh nebulizer, delivery was highest when using high-frequency oscillator ventilator in the neonatal and pediatric models, and with the nebulizer in the distal position in the adult model. Conclusions: The vibrating mesh nebulizer is a suitable alternative to the Tyvaso Inhalation System for inhaled treprostinil delivery. Fine particle fraction is similar between devices, and vibrating mesh nebulizer delivery meets or exceeds delivery of the Tyvaso Inhalation System. Delivery for infants and children during high-frequency oscillator ventilator with the vibrating mesh nebulizer may result in higher than expected dosages. (C)2017The Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies
from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2qc0F2V
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Chronic exposure to high altitude may lead to hyperuricemia. We investigated the prevalence of hyperuricemia and its risk factors...
-
Objectives: To compare the performance of critical care providers with that of electroencephalography experts in identifying seizures using ...
-
Objectives: To describe the regionality and seasonality of respiratory syncytial virus-associated hospital and ICU admissions for 10 consecu...
-
Abstract Background and Objectives Subdural hematoma (SDH) is the most common form of traumatic intracranial hemorrhage. Severity of dis...
-
Publication date: Available online 6 October 2018 Source: The Journal of Emergency Medicine Author(s): Abdallah Rebeiz, Roula Sasso, Rana...
-
Abstract Background To investigate the relationships between sagittal parameters and health-related quality of life (HRQOL) scores follo...
-
The American Journal of Emergency Medicine from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/28IB6n3
-
http://bit.ly/2saJoKg
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου