Objectives: To determine the feasibility of delivering inhaled treprostinil during mechanical ventilation and spontaneous unassisted ventilation using the Tyvaso Inhalation System and the vibrating mesh nebulizer. We sought to compare differences in fine particle fraction, and absolute inhaled treprostinil mass delivered to neonatal, pediatric, and adult models affixed with a face mask, conventional, and high-frequency ventilation between Tyvaso Inhalation System and with different nebulizer locations between Tyvaso Inhalation System and vibrating mesh nebulizer. Design: Fine particle fraction was first determined via impaction with both the Tyvaso Inhalation System and vibrating mesh nebulizer. Next, a test lung configured with neonatal, pediatric, and adult mechanics and a filter to capture medication was attached to a realistic face model during spontaneous breathing or an endotracheal tube during conventional ventilation and high-frequency oscillator ventilator. Inhaled treprostinil was then nebulized with both the Tyvaso Inhalation System and vibrating mesh nebulizer, and the filter was analyzed via high-performance liquid chromatography. Testing was done in triplicate. Independent two-sample t tests were used to compare mean fine particle fraction and inhaled mass between devices. Analysis of variance with Tukey post hoc tests were used to compare within device differences. Setting: Academic children's hospital aerosol research laboratory. Measurements and Main Results: Fine particle fraction was not different between the Tyvaso Inhalation System and vibrating mesh nebulizer (0.78 +/- 0.04 vs 0.77 +/- 0.08, respectively; p = 0.79). The vibrating mesh nebulizer delivered the same or greater inhaled treprostinil than the Tyvaso Inhalation System in every simulated model and condition. When using the vibrating mesh nebulizer, delivery was highest when using high-frequency oscillator ventilator in the neonatal and pediatric models, and with the nebulizer in the distal position in the adult model. Conclusions: The vibrating mesh nebulizer is a suitable alternative to the Tyvaso Inhalation System for inhaled treprostinil delivery. Fine particle fraction is similar between devices, and vibrating mesh nebulizer delivery meets or exceeds delivery of the Tyvaso Inhalation System. Delivery for infants and children during high-frequency oscillator ventilator with the vibrating mesh nebulizer may result in higher than expected dosages. (C)2017The Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies
from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2qc0F2V
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract Purpose Children with sagittal craniosynostosis (SC) are at risk of developing raised intracranial pressure (ICP). This is thou...
-
Abstract Objective Among different PET tracers, 18 F-fludeoxyglucose (FDG) and 11 C-choline are known to have a high tumor uptake correl...
-
Abstract Background Poor indoor air quality is a great problem in schools due to a high number of students per classroom, insufficient o...
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2aggaBB
-
Urology from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/1WbRhbQ
-
Alternative treatments for opioid use disorder and music with Dr. Ed Boyer Join Dan (@drusyniak) &Howard (@heshiegreshie) as they speak...
-
Abstract The aim of this study was to prepare an injectable DNA-loaded nano-calcium phosphate paste that is suitable as bioactive bone sub...
-
Abstract Medial knee pain is common in clinical practice and can be caused by various conditions. In rare cases, it can even be by calcifi...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου