Objectives: Tight glycemic control using intermittent blood glucose measurements is associated with a risk of hypoglycemia. Glucose concentrations can now be measured near continuously (every 5–15 min). We assessed the quality and safety of glycemic control guided by a near-continuous glucose monitoring system in ICU patients. Design: Prospective, cluster-randomized, crossover study. Setting: Thirty-five–bed medico-surgical department of intensive care with four separate ICUs. Patients: Adult patients admitted to the department and expected to stay for at least 3 days were considered for inclusion if they had persistent hyperglycemia (blood glucose > 150 mg/dL) up to 6 hours after admission and/or were receiving insulin therapy. Interventions: A peripheral venous catheter was inserted in all patients and connected to a continuous glucose monitoring sensor (GlucoClear; Edwards Lifesciences, Irvine, CA). The four ICUs were randomized in pairs in a crossover design to glycemic control using unblinded or blinded continuous glucose monitoring monitors. The insulin infusion rate was adjusted to keep blood glucose between 90 and 150 mg/dL using the blood glucose values displayed on the continuous glucose monitor (continuous glucose monitoring group—unblinded units) or according to intermittent blood glucose readings (intermittent glucose monitoring group—blinded units). Measurements and Main Results: The quality and safety of glycemic control were assessed using the proportion of time in range, the frequency of blood glucose less than 70 mg/dL, and the time spent with blood glucose less than 70 mg/dL (TB70), using blood glucose values measured by the continuous glucose monitoring device. Seventy-seven patients were enrolled: 39 in the continuous glucose monitoring group and 38 in the intermittent glucose monitoring group. A total of 43,107 blood glucose values were recorded. The time in range was similar in the two groups. The incidence of hypoglycemia (8/39 [20.5%] vs 15/38 [39.5%]) and the TB70 (0.4% ± 0.9% vs 1.6% ± 3.4%; p
from Emergency Medicine via xlomafota13 on Inoreader https://ift.tt/2Hhqurk
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Abstract The application of statistics has been instrumental in clarifying our understanding of the genome. While insights have been deriv...
-
Abstract Chronic exposure to high altitude may lead to hyperuricemia. We investigated the prevalence of hyperuricemia and its risk factors...
-
Paramedic Charles Robichaud calls on voters to consider him as a write-in candidate in the 2016 presidential election from EMS via xlomafo...
-
Publication date: Available online 17 January 2018 Source: The Journal of Emergency Medicine Author(s): Jason M. Block, Chris F. Allison,...
-
Abstract In this paper, a new approach is proposed to extract an ordered sequence of curvilinear structures in images, capturing the large...
-
Can We Reduce Frame Rate to 15 Images per Second in Pediatric Videofluoroscopic Swallow Studies? Abstract Videofluoroscopic Swallow studies ...
-
Objectives: To evaluate test validity of the Pediatric Confusion Assessment Method for the ICU, the Pediatric Anesthesia Emergence Delirium...