Objectives: Rigid cervical collars are known to increase intracranial pressure (ICP) in severe traumatic brain injury (TBI). Cerebral blood flow might decrease according to the Kellie Monroe doctrine. For this reason, the use of the collar in patients with severe TBI has been abandoned from several trauma protocols in the Netherlands. There is no evidence on the effect of a rigid collar on ICP in patients with mild or moderate TBI or indeed patients with no TBI. As a first step we tested the effect in healthy volunteers with normal ICPs and intact autoregulation of the brain. Methods: In this prospective blinded cross-over study, we evaluated the effect of application of a rigid cervical collar in 45 healthy volunteers by measuring their optical nerve sheath diameter (ONSD) by transocular sonography. Sonographic measurement of the ONSD behind the eye is an indirect noninvasive method to estimate ICP and pressure changes. Results: We included 22 male and 23 female volunteers. In total 360 ONSD measurements were performed in these 45 volunteers. Application of a collar resulted in a significant increase in ONSD in both the left ([beta]=0.06, 95% confidence interval: 0.05-0.07, P
from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2uNpcl4
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2gDH2gG
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2aggaBB
-
Correction to: Ecological risk assessment of metals in sediments and selective plants of Uchalli Wetland Complex (UWC)—a Ramsar site The cor...
-
The American Journal of Emergency Medicine from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2vqK26U
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2dbgxvK
-
Acuity Link, ZOLL integrate solutions to drive accuracy and efficiency in medical transport dispatchYARMOUTH PORT, Mass. – Acuity Link, a provider of software solutions used to automate and optimize non-emergency medical transportation (NEM...
-
Complex effects of continuous vasopressor infusion on fluid responsiveness during liver resection: A preliminary randomised controlled trial...
-
from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2mrxObF
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου