Objective: Mechanically ventilated neonates have been observed to receive substantially different ventilation after switching ventilator models, despite identical ventilator settings. This study aims at establishing the range of output variability among 10 neonatal ventilators under various breathing conditions. Design: Relative benchmarking test of 10 neonatal ventilators on an active neonatal lung model. Setting: Neonatal ICU. Subjects: Ten current neonatal ventilators. Interventions: Ventilators were set identically to flow-triggered, synchronized, volume-targeted, pressure-controlled, continuous mandatory ventilation and connected to a neonatal lung model. The latter was configured to simulate three patients (500, 1,500, and 3,500 g) in three breathing modes each (passive breathing, constant active breathing, and variable active breathing). Measurements and Main Results: Averaged across all weight conditions, the included ventilators delivered between 86% and 110% of the target tidal volume in the passive mode, between 88% and 126% during constant active breathing, and between 86% and 120% under variable active breathing. The largest relative deviation occurred during the 500 g constant active condition, where the highest output machine produced 147% of the tidal volume of the lowest output machine. Conclusions: All machines deviate significantly in volume output and ventilation regulation. These differences depend on ventilation type, respiratory force, and patient behavior, preventing the creation of a simple conversion table between ventilator models. Universal neonatal tidal volume targets for mechanical ventilation cannot be transferred from one ventilator to another without considering necessary adjustments. (C)2017The Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies
from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2klNxpC
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2gDH2gG
-
Background: Although cervical spine CT (CSCT) accurately detects bony injuries, it may not identify all soft tissue injuries. While some cli...
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2aggaBB
-
The day before Thanksgiving, DC Fire and EMS stopped by a homeless encampment to distribute some food. from EMS via xlomafota13 on Inoread...
-
Chief Wylie discusses a host of issues surrounding firefighters being armed. If you're going to carry a weapon on duty, one of your prim...
-
By Harriet Howard Heithaus Naples Daily NORTH NAPLES, Fla. — When firefighter-paramedics opened the door of Station No. 46 in North Naples...
-
What happened: Emergency Medical Responder and EMT student Daniel Wesley , 17, is recovering from two gunshot wounds, a broken arm and a br...
-
Abstract Background and aims The clinical course and responsiveness to antiviral treatments differs among hepatitis B virus (HBV) genoty...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου