Objectives: Renal replacement therapy in infants and small children is the treatment of choice for severe oligoanuric renal dysfunction, with an increasing consensus that early initiation might contribute to preventing acute kidney injury complications. Safer renal replacement therapy devices specifically designed for neonates may contribute to ameliorating outcomes and increasing chances of survival. One of the crucial factors to achieve an effective renal replacement therapy in small infants is adequate vascular access. The interaction of small size central vascular catheters with renal replacement therapy devices has never been investigated. The aim of this study was to characterize both the operating conditions and performance of three different central vascular catheters sizes (4F, 5F, and 7F) connected to two different extracorporeal blood circulation models (adult and pediatric). The rheologic performance of each vascular access size in combination with the adult and pediatric renal replacement therapy models was described. Design: Series of experimental extracorporeal circulation circuit tests were conducted with different setups. A two-roller pump was used to simulate a standard adult dialysis machine, whereas a small three-roller pump served as pediatric renal replacement therapy device. Setting: A pressure-flow setup aimed to collect pressure and flow values under different test conditions. A second experiment focused on hemolysis estimation induced by the extracorporeal system. Hemolysis exclusively induced by the 4F catheter was also evaluated. Finally, our data were applied to estimate the optimal catheter size theoretically capable of delivering adequate doses basing on anthropometric data (patient weight and cannulation site) in absence of direct ultrasound vessel measurement. Subjects: In vitro tests conducted on simulated extracorporeal circuit models of continuous pediatric and neonatal renal replacement therapy. Interventions: None. Measurements and Main Results: When 4F and 5F catheters are used, maximal blood flows within safe circuit pressures can be set at the values of 13 and 29 mL/min, respectively, when a small pump is used. Differently, when using adult roller pumps, only maximal flows of 10 and 20 mL/min are reached. However, hemolysis is higher when using a three-roller pump compared with the two-roller. The clinical impact of this increased hemolytic burden is likely not relevant. Conclusions: Small size central vascular catheters display optimal rheologic performances in terms of pressures and flows particularly when the renal replacement therapy device is equipped with pumps proportional to central vascular catheters sizes, and even when relatively high blood flows are set. This is achieved at the risk of a higher hemolysis rate. Supplemental digital content is available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal’s website (https://ift.tt/2gIrZ5Y). Mr. Garzotto, Ms. Zaccaria, Dr. Vidal, and Mr. Ruggeri contributed to the study conception and design. Mr. Garzotto, Ms. Zaccaria, Ms. Lorenzin, and Mr. Neri performed the ex vivo-tests. Mr. Garzotto, Drs. Vidal and Ricci, and Mr. Ruggeri contributed to the data analysis and to the technical interpretation. Mr. Garzotto and Drs. Vidal, Ricci, Nalesso, and Ronco contributed to the clinical interpretation. Ms. Zaccaria, Ms. Lorenzin, and Mr. Neri contributed to data collection and elaboration. Mr. Garzotto, Drs. Vidal and Ricci, and Ms. Murer, and Dr. Nalesso drafted the article. Dr. Ricci critically reviewed the article. All authors critically revised the article for important intellectual content and approved the final version to be published. The authors have disclosed that they do not have any potential conflicts of interest. For information regarding this article, E-mail: f.garzotto@gmail.com ©2018The Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies
from Emergency Medicine via xlomafota13 on Inoreader https://ift.tt/2C60mzD
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
As with many uncommon situations that are unique to critical illness, we cannot always rely on specialist consultation. Critical care prac...
-
Publication date: Available online 24 October 2016 Source: The Journal of Emergency Medicine Author(s): Abigail M. Schuh, Eileen J. Klein...
-
Editorial Radioiodine: 80 years and counting; the past, present, and future by Matthew D Ringel Thematic Review Radioiodine treatment: an h...
-
Big dreams to improve EMS with a windfall of funding for safety, health and wellness, research and leadership development from EMS via xlo...
-
Mitigate the effects a career in EMS can take to nurture your career longevity in EMS from EMS via xlomafota13 on Inoreader https://ift.tt...
-
Objectives: The Pediatric Acute Lung Injury Consensus Conference developed a pediatric specific definition for acute respiratory distress s...
-
Resuscitation is a System I Game... EMCrit by Scott Weingart . from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/1Svu...
-
Injury from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2atuoga
-
Consent and Autonomy in the Genomics Era Abstract Purpose of Review Genomic tests offer increased opportunity for diagnosis, but their outpu...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου