Objectives: Low tidal volume (= tidal volume ≤ 6 mL/kg, predicted body weight) ventilation using volume control benefits patients with acute respiratory distress syndrome. Airway pressure release ventilation is an alternative to low tidal volume-volume control ventilation, but the release breaths generated are variable and can exceed tidal volume breaths of low tidal volume-volume control. We evaluate the application of a low tidal volume-compatible airway pressure release ventilation protocol that manages release volumes on both clinical and feasibility endpoints. Design: We designed a prospective randomized trial in patients with acute hypoxemic respiratory failure. We randomized patients to low tidal volume-volume control, low tidal volume-airway pressure release ventilation, and traditional airway pressure release ventilation with a planned enrollment of 246 patients. The study was stopped early because of low enrollment and inability to consistently achieve tidal volumes less than 6.5 mL/kg in the low tidal volume-airway pressure release ventilation arm. Although the primary clinical study endpoint was PaO2/FIO2 on study day 3, we highlight the feasibility outcomes related to tidal volumes in both arms. Setting: Four Intermountain Healthcare tertiary ICUs. Patients: Adult ICU patients with hypoxemic respiratory failure anticipated to require prolonged mechanical ventilation. Interventions: Low tidal volume-volume control, airway pressure release ventilation, and low tidal volume-airway pressure release ventilation. Measurements and Main Results: We observed wide variability and higher tidal (release for airway pressure release ventilation) volumes in both airway pressure release ventilation (8.6 mL/kg; 95% CI, 7.8–9.6) and low tidal volume-airway pressure release ventilation (8.0; 95% CI, 7.3–8.9) than volume control (6.8; 95% CI, 6.2–7.5; p = 0.005) with no difference between airway pressure release ventilation and low tidal volume-airway pressure release ventilation (p = 0.58). Recognizing the limitations of small sample size, we observed no difference in 52 patients in day 3 PaO2/ FIO2 (p = 0.92). We also observed no significant difference between arms in sedation, vasoactive medications, or occurrence of pneumothorax. Conclusions: Airway pressure release ventilation resulted in release volumes often exceeding 12 mL/kg despite a protocol designed to target low tidal volume ventilation. Current airway pressure release ventilation protocols are unable to achieve consistent and reproducible delivery of low tidal volume ventilation goals. A large-scale efficacy trial of low tidal volume-airway pressure release ventilation is not feasible at this time in the absence of an explicit, generalizable, and reproducible low tidal volume-airway pressure release ventilation protocol.
from Emergency Medicine via xlomafota13 on Inoreader https://ift.tt/2zVrvCI
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Champion EMS is currently seeking a Communications Center Manager. Champion EMS is based out of Longview, Texas, serving the East Texas area...
-
from EMS via xlomafota13 on Inoreader http://ift.tt/2sbML2K
-
The name of the second author of this article was incorrectly presented as "Riccardo Scarpa Cosimo" this should have been "Co...
-
Abstract Given shifting sex work criminalization and enforcement in Canada, this study examined worrying about workplace inspections by au...
-
Abstract Introduction In recent years, platelet-rich plasma (PRP) has emerged as a promising autologous biological treatment modality fo...
-
Abstract Background Permissive hypotensive resuscitation (PHR) is an advancing concept aiming towards deliberative balanced resuscitation ...
-
from EMS via xlomafota13 on Inoreader http://ift.tt/2sbML2K
-
While the psychiatric disorders are conditions frequently encountered in hospitalized patients, there are little or no data regarding the ch...
-
No abstract available from Emergency Medicine via xlomafota13 on Inoreader https://ift.tt/2Tlj4K7
Δεν υπάρχουν σχόλια: