INTRODUCTION: We have previously demonstrated that tight glycemic control (80-120 mg/dl) improves outcome in critically injured patients. However, many centers have gotten away from aggressive glucose control due to the workload and risk of hypoglycemia. The objective of this pivotal trial is to evaluate the first in human continuous inline glucose monitor (OptiScanner) in critically ill patients. METHODS: A multicenter pivotal trial was conducted over a 1 year period (2014-2015) at 4 major academic centers in 200 critically ill patients. 3735 glucose measurements were obtained and measured. A paired blood sample was then collected to coincide with the OptiScan measurement. The OptiScanner withdraws 0.13 ml of blood every 15 minutes from a central venous line, centrifuges the sample, and uses mid-infrared spectroscopy to directly measure glucose levels in blood plasma. We plotted a Clarke Error Grid, calculated Mean Absolute Relative Deviation (MARD) to analyze trend accuracy, and Population Coefficient of Variance (PCV) to measure deviations. OptiScanner and YSI values were "blinded" from clinicians. Treatment was guided by the standard point of care meters. RESULTS: 95.4% of the data points were in zone A of the Clarke Error Grid and 4.5% in zone B. The MARD was 7.6%, the PCV 9.6%. The majority of data points achieved the benchmark for accuracy. The MARD was below 10%, which is the first inline continuous glucose monitor to achieve this result in a clinical trial. The PCV was less than 10%, We confirmed that the OptiScanner outperformed every 1 to 3 hour glucose measurements using point of care meters which prevents glucose excursions and variability and achieves a higher amount of time the patient's glucose values remain in range. CONCLUSION: This pivotal multicenter trial demonstrates that the first inline CGM monitor is safe and accurate for use in critically ill surgical and trauma patients. (C) 2017 Lippincott Williams & Wilkins, Inc.
from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2nfhrzE
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Morphology of the Middle Ear Ossicles in the Rodent Perimys (Neoepiblemidae) and a Comprehensive Anatomical... Morphology of the Middle Ear ...
-
The science behind successful learning, classroom teaching and clinical precepting in EMS from EMS via xlomafota13 on Inoreader https://if...
-
Ann & Robert H. Lurie Children's Hospital of Chicago News from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2awqX...
-
Resuscitation from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2aUSu4k
-
Abstract This Strategic Research Agenda identifies current challenges and needs in healthcare, illustrates how biomedical imaging and deri...
-
An error was made to a contributor address for the article “Diagnosis and Treatment of Central Nervous System Infections in the Emergency De...
-
Acquiring the Skill of Identifying Fractions through the Virtual-Abstract Framework Abstract Fractions are an important component of mathema...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου