INTRODUCTION: We have previously demonstrated that tight glycemic control (80-120 mg/dl) improves outcome in critically injured patients. However, many centers have gotten away from aggressive glucose control due to the workload and risk of hypoglycemia. The objective of this pivotal trial is to evaluate the first in human continuous inline glucose monitor (OptiScanner) in critically ill patients. METHODS: A multicenter pivotal trial was conducted over a 1 year period (2014-2015) at 4 major academic centers in 200 critically ill patients. 3735 glucose measurements were obtained and measured. A paired blood sample was then collected to coincide with the OptiScan measurement. The OptiScanner withdraws 0.13 ml of blood every 15 minutes from a central venous line, centrifuges the sample, and uses mid-infrared spectroscopy to directly measure glucose levels in blood plasma. We plotted a Clarke Error Grid, calculated Mean Absolute Relative Deviation (MARD) to analyze trend accuracy, and Population Coefficient of Variance (PCV) to measure deviations. OptiScanner and YSI values were "blinded" from clinicians. Treatment was guided by the standard point of care meters. RESULTS: 95.4% of the data points were in zone A of the Clarke Error Grid and 4.5% in zone B. The MARD was 7.6%, the PCV 9.6%. The majority of data points achieved the benchmark for accuracy. The MARD was below 10%, which is the first inline continuous glucose monitor to achieve this result in a clinical trial. The PCV was less than 10%, We confirmed that the OptiScanner outperformed every 1 to 3 hour glucose measurements using point of care meters which prevents glucose excursions and variability and achieves a higher amount of time the patient's glucose values remain in range. CONCLUSION: This pivotal multicenter trial demonstrates that the first inline CGM monitor is safe and accurate for use in critically ill surgical and trauma patients. (C) 2017 Lippincott Williams & Wilkins, Inc.
from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2nfhrzE
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2dbgxvK
-
JAMA Otolaryngology Author Interview: Tinnitus Retraining Therapy vs Standard of Care and Tinnitus-Related Quality of LifeVIEWPOINTThe Searc...
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2gDH2gG
-
Sonication of removed implants improves microbiological diagnosis of postoperative spinal infectionsAbstract Purpose In total joint replacement, culturing of the sonication fluid of removed implants has proven to be more sensitive than ...
-
IRVINE, Calif. — In an effort to help firefighters cover the high cost of cancer treatment as a result of the occupational risk of experienc...
-
Objective: The objective of this article is to provide a summary of the perceptions of healthcare providers and family members toward their ...
-
Note: Page numbers of article titles are in boldface type. from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/2aggaBB
-
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182, 64 Journals 1aky08-3m5n7.htmlInternati...
-
Objectives: The aim of this study was to identify the impact of antifungal prevention in critically ill immunocompetent adult patients on mo...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου