Accuracy of Latarjet graft and screw position after using novel drill guide

Abstract

Purpose

For the success of Latarjet procedure a correct graft positioning is mandatory. Furthermore, the correct screw placement is important to avoid cartilage damage and soft tissue irritation. Due to a cadaveric experimental study, the accuracy of graft and screw positioning utilizing a novel drill guide for a minimal-invasive Latarjet procedure was analyzed.

Methods

Five human fresh-frozen shoulder specimens have been treated in accordance with the Congruent-Arc Latarjet technique using the glenoid bone loss set (Arthrex, Naples, FL, USA) with 3.75 mm cannulated screws throughout a 5 cm skin incision without detachment of the scapularis tendon. All procedures were performed by one single, experienced shoulder surgeon. The accuracy of graft and screw positioning was assessed due to a CT scan.

Results

A noticeable learning curve was noted during the study period as the first surgery took 45 min and the last 33 min. All grafts were correctly positioned with regard to the articular line of the glenoid surface. Impingement with the maximum head circumference was not encountered. The screw positions did not affect the suprascapular nerve. A damage of the graft was not noticed.

Conclusions

The authors can recommend the usage of the new drill guide tested in this study. It seems to be beneficial in the Latarjet procedure and may ease correct graft positioning and prevent screw misplacement. Compared to fully arthroscopically performed Latarjet procedures it provides much steeper learning curve and seems technically easier and quicker to handle.



from Emergency Medicine via xlomafota13 on Inoreader http://ift.tt/29nxG7e

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Δημοφιλείς αναρτήσεις